Skočit na hlavní menu Skočit na obsah

BETACONTROL


  • Vxfdtahy
  • Bezpečný dům
  • Čerpací stanice
  • Marketing

Vyhledávání


  • Novinky
  • O firmě
  • Kontakty
  • Volná místa
Zpět nahoru

Hlavní menu

  • Česky
  • English
  • Русский
  • Výtahy
  • Bezpečný dům
  • Čerpací stanice
  • Marketing
  • Partneři
Zpět nahoru
PoÚtStČtPáSoNe
<září 2010>
  12345
6789101112
13141516171819
20212223242526
27282930   

Stará verze webu

ADPMPD/T electronic calculator

ADP/T calculators are the latest calculator types of ADP line. They issue from the predecessor ADP/M line of calculators.

ADPMPD/T electronic calculator for fuel dispenser control

  • new concept - resumes ADP/M line

  • compact design

  • error history

  • thermally protected motor control

  • wide range supply voltage

  • new compact LCD with integrated illumination

  • delivery flow controlled via a proportional valve or a closing/throttle valve (alternatively)


Brief characteristics:

The calculator controls a fuel dispenser with one or two fuelling points. Up to five nozzles may be at each fuelling point. ADPMPD/T calculator technical parameters equal world standard.

ADPMPD/T type electronic calculator is an electronic control system for fuel distribution at the modern fuel sites. ADPMPD/T can operate in either the standalone (manual) or the communication mode. The calculator uses communication protocol EASYCALL that is also implemented in the widely used site controllers and POSes - for instance DOMS, PetroVend and others.

The calculator covers all necessary functions to control a fuel dispenser - no additional electronic modules are required to be installed.

Setting the calculator parameters guarantees the flexibility of the function. The parameters are compatible with the other Beta Control calculators. The calculator parameters, unit prices, electronic calibration values and the ATC can be set using the wireless keyboards over the infra-red transmission.

The calculator is equipped with one display for each fuelling point (side). The displays show the process of transactions and other data important for calculator operation (setting, auto-diagnostics, etc.) The displays of LCD type may be delivered in various versions (positive, blue negative, or other). Calculator internal bus that connects the displays may also connect other devices such as special purpose modules, keyboards, voice module and others.

The calculator is equipped with non reset-able built-in electronic volume total register of the meters and electronic registers of volume, price and number of transactions totals per nozzle. Nozzle electronic registers may be recorded via the communication line.
In addition, an electromechanical non reset-able volume total register may be installed for each meter.

Shaft encoders used to transmit measured delivered volume from the meter to calculator electronics may be chosen as three-channel or two-channel type.

Each ADPMPD/T calculator fuelling point can connect a customer pre-selection keyboard. Customers may use the keyboard to pre-set the volume to be delivered or the total price of the fuel to be delivered.

Calculator electronics is encased in a metal box that may easily be attached in the dispenser. Every input and output connects with screw terminal connectors via cables. The used connectors are designed so that the calculators may be easily replaced in case of fault because all wires remain connected to the connectors even if these are opened.

Basic technical parameters:

Supply voltage

230 V ±15 %, 50 Hz/60 Hz

Power requirement

50 VA max.

Operation temperature

-40 °C till +70 °C (DISPLCD/N -25 °C till +70 °C)

Relative humidity

0-80 % without condensation

Weight

4.9 kg

Dimensions

263x282x117 mm

Maximum measurable flow

680 l/min

Maximum frequency of electromechanical total counters

7 Hz

Used shaft encoders

three- or two-channel, supply voltage 5 V DC, Open collector output

Number of products per side

5

Displays

seven segment LCD, integrated LED illumination,
total price 6 digits, volume 6 digits, unit price 4 digits,
character size 25.4 mm (one inch)

Valid data display time

minimum 30 minutes after supply voltage shut-down

Maximum output load

motor contactors, reduction valve, closing valve
230 V AC, max.10 VA
proportional valves 24 V, max.16 W

Communication interface

RS485 two-wire half-duplex
or IFSF/LON interface



Zpět nahoru

Novinky z Bety

  • 05.08. 2010 - Podporujeme FK Blansko
  • 02.06. 2010 - Soutěž krásy - fotky
  • 20.05. 2010 - Miss Přehrada 2010
  • 19.05. 2010 - Stojan ADAST MAJOR ECO získal cenu Výrobek roku 2010.
  • 17.03. 2010 - Pozvánka na prezentaci
Archiv

Novinky

  • 03.09. 2010 - Veletrh FOR ARCH představí přes pět set vystavovatelů
  • 03.09. 2010 - Světlo v nových obalech
  • 26.08. 2010 - Omezení podpory stavebního spoření podle ČSRB úspory nepřinese
Archiv
Zpět nahoru
© 2008-2010 BETACONTROL